Skip to content

Munkah 4

Cooper, Queensland

Munkah 4 is a petroleum well in the Cooper, Queensland, operated by Santos, drilled to a total depth of 2,401 m.

Request LAS Files & Well Summary

Well Information

Well Name
Munkah 4
Basin
Cooper
State
Queensland
Classification
NDFE
Operator
Santos
Driller
ODE

Drilling Data

Total Depth
2,401 m
Datum Elevation
79.0 m
Spud Date
08/04/1993
Completion Date
30/04/1993
Permit
-
Rig
Rig 18

Location

Latitude
-27.4322
Longitude
141.9050

Available Log Data

1
Log Streams
21
Curves
197,246
Data Points
30,060
Metres

Caliper (2 curves)

Borehole diameter measurements indicating hole condition and washout zones.

Curve Start End Interval
CALI 1705 m 2377 m 672 m
CALI 482 m 2390 m 1907 m

Chromato (5 curves)

Well log curves recorded during wireline logging operations.

Curve Start End Interval
BUTA 1795 m 2350 m 555 m
ETHA 1233 m 2401 m 1168 m
METH 160 m 2401 m 2241 m
PENT 2034 m 2359 m 324 m
PROP 1748 m 2401 m 652 m

Density (3 curves)

Bulk density measurements for porosity calculation and lithology identification.

Curve Start End Interval
DRHO 1705 m 2377 m 672 m
PEF 1705 m 2377 m 672 m
RHOB 1705 m 2382 m 677 m

GR (1 curves)

Well log curves recorded during wireline logging operations.

Curve Start End Interval
GR 29 m 2370 m 2340 m

Miscellaneous (1 curves)

Well log curves recorded during wireline logging operations.

Curve Start End Interval
DEPTH 6 m 2401 m 2394 m

Mudlog (2 curves)

Well log curves recorded during wireline logging operations.

Curve Start End Interval
ROP 6 m 2401 m 2394 m
TGAS 292 m 2401 m 2108 m

Neutron (1 curves)

Porosity measurements derived from neutron or density tools, indicating reservoir storage capacity.

Curve Start End Interval
NPHI 1705 m 2377 m 672 m

Resistivity (3 curves)

Electrical resistivity logs used to evaluate fluid content and identify hydrocarbon-bearing zones.

Curve Start End Interval
LLD 482 m 2382 m 1900 m
LLS 482 m 2385 m 1903 m
MSFL 1307 m 2394 m 1087 m

Sonic (2 curves)

Acoustic travel time logs used for porosity estimation and seismic calibration.

Curve Start End Interval
DT 481 m 2398 m 1917 m
DTL 481 m 2398 m 1917 m

SP (1 curves)

Spontaneous potential logs measuring natural electrical potentials for permeability indication.

Curve Start End Interval
SP 482 m 2362 m 1880 m